The Function of a Flash Mix Tank on a Slant Plate Clarifier

A flash mix tank is a crucial component in a slant plate clarifier used for wastewater treatment and solids separation. It plays a significant role in the initial stage of the clarifying process, where the goal is to facilitate the coagulation and flocculation of suspended solids, making them easier to separate from the water.

The flash mix tank's purpose is to promote the rapid formation of flocs and ensure that the coagulants are effectively distributed throughout the wastewater. This pre-treatment step is critical in the overall solids separation process within a slant plate clarifier, as it sets the stage for efficient particle removal during sedimentation.

In today’s blog we will look at the process of a flash mix tank and how it facilitates settling in the slant plate clarifier.

Process of a Flash Mix Tank

Introduction of Coagulants: The process begins with the introduction of coagulants into the wastewater. Coagulants are chemicals (such as alum or ferric chloride) that help destabilize and aggregate suspended particles by neutralizing the charges on their surfaces.

The amount of coagulant to add to a flash mix tank in wastewater treatment depends on various factors, including the characteristics of the wastewater, the type of coagulant being used, the desired treatment goals, and the system's design. There is no one-size-fits-all answer to the question of how much coagulant to add because it requires consideration of these variables. However, there are some general guidelines on determining the coagulant dosage:

  • Jar Tests: Jar tests are commonly performed in a laboratory or pilot-scale setting to determine the optimal coagulant dosage. Small samples of wastewater are mixed with varying amounts of coagulant, then the floc formation and settling characteristics are observed. The dosage that produces the best results (e.g., effective floc formation, rapid settling) is then applied to the full-scale treatment process.

  • Wastewater Characteristics: The coagulant dosage depends on the specific characteristics of the wastewater, such as its turbidity, pH, temperature, and the nature of the suspended solids. Wastewater with high turbidity or a high concentration of suspended solids may require a higher coagulant dosage.

  • Coagulant Type: Different coagulants (e.g., aluminum-based or iron-based coagulants) have varying dosing requirements. The choice of coagulant depends on the wastewater's composition and treatment goals.

  • Treatment Goals: The desired treatment goals play a significant role in determining the coagulant dosage. For example, if the goal is to achieve a certain level of turbidity removal or a specific reduction in a particular pollutant, the dosage may be adjusted accordingly.

  • System Design: The design of the flash mix tank and the entire treatment system can influence the coagulant dosage. The tank's size, mixing intensity, and retention time can all affect the required dosage.

  • Regulatory Requirements: Compliance with regulatory standards for effluent quality may dictate minimum coagulant dosages to achieve specific treatment levels.

  • Operator Experience: Experienced wastewater treatment operators often play a crucial role in fine-tuning coagulant dosages based on their knowledge of the system and its performance.

  • It's important to note that overdosing coagulants can lead to issues such as increased chemical costs, excessive sludge production, and potential harm to the environment. Therefore, precise dosing and ongoing monitoring of treatment performance are essential.

  • To determine the appropriate coagulant dosage for your specific wastewater treatment system, it is advisable to consult with a water treatment specialist or conduct jar tests and pilot-scale experiments to optimize the process for your particular conditions.

Mixing: The wastewater, along with the coagulants, enters the flash mix tank. Inside the tank, rapid and vigorous mixing takes place. The mixing is typically achieved using mechanical agitators, by injecting compressed air, or recirculating the flow to create turbulence. This intense mixing promotes the dispersion of coagulants throughout the wastewater, ensuring uniform contact between the coagulants and suspended particles.

Flocculation: As the coagulants disperse and interact with the suspended particles, they begin to neutralize the charges on the particles' surfaces. This process promotes the formation of small flocs, or aggregates, as the particles come together. The mixing energy in the flash mix tank should be sufficient to promote collision and adhesion between these particles, resulting in the formation of larger flocs.

  • Flocculation Potential: While the primary goal of the flash mix tank is to promote coagulation (bringing particles together), the energy and turbulence in the tank can also initiate some degree of flocculation (floc growth and maturation). The effectiveness of flocculation in the flash mix tank depends on factors like mixing intensity, coagulant dosage, and the nature of the particles in the wastewater.

Retention Time: The wastewater and coagulant mixture typically spend a short but controlled amount of time in the flash mix tank. This duration, known as the retention time, allows sufficient time for coagulation and initial flocculation to occur but is typically brief to prevent over-aggregation or settling within the tank.

Retention Time (RT)= Volume (V) / Flow Rate (Q)

Where:

RT (Retention Time) is measured in minutes, hours, or any desired time unit.

V (Volume) is the volume of the vessel or system in which the substance or fluid is contained. This volume should be expressed in consistent units (e.g., liters, gallons, cubic meters).

Q (Flow Rate) is the rate at which the substance or fluid enters or exits the system. The flow rate should also be expressed in consistent units (e.g., liters per minute, gallons per hour).

Here are some key points to consider when using this formula:

Consistent Units: Make sure that both the volume and flow rate are expressed in the same units. If necessary, convert one or both to match the units of the other.

Time Units: The retention time will be in the time unit that corresponds to the flow rate (e.g., minutes if the flow rate is in liters per minute).

System Boundaries: Clearly define the boundaries of the system for which you are calculating retention time. Ensure that you are considering the correct volume and flow rate related to that specific system.

Steady-State vs. Transient Conditions: The formula assumes steady-state conditions, meaning that the flow rate and volume remain constant over the specified period. If the conditions are not steady-state, you may need to consider changes in flow rate or volume over time.

Interpretation: The retention time represents the average time a substance or fluid spends in the system. It can be useful for determining reaction kinetics, treatment efficiency, or residence times in various processes.

As an example, if you are designing a wastewater treatment tank with a volume of 10,000 liters and a flow rate of 1,000 liters per hour, the retention time would be:

RT= 10,000 liters / 1,000 liters per hour =10 hours

In this example, the wastewater would spend an average of 10 hours within the treatment tank before exiting.

Effluent Separation: After the flash mixing stage, the mixture flows into the slant plate clarifier or sedimentation basin. In this part of the clarifier, the flocculated particles settle out of the water due to gravity. The slant plates are designed to enhance the settling process by providing a large surface area for the flocs to settle on. As the flocs settle to the bottom, they form a sludge layer that can be removed later, leaving clarified water at the top.

Call J.Mark Systems Today

Are you looking into a high-quality slant plate clarifier for your wastewater treatment? Look no further. J.Mark Systems has precisely what you need. Our systems come backed by years of experience providing high-quality water filtration systems for industrial water supply.

We’ll walk you through every step of the process and get you the perfect slant
plate clarifier for your system; from performing a water optimization audit to installing and monitoring your system. Contact J.Mark Systems today to get started or for more information. 

Previous
Previous

Ways That Water Reuse and Reclamation Promote Sustainability

Next
Next

Understanding Slant Plate Clarifier Sizing & Rating